Search

Products tagged with 'process steam'

6745 kw Siemens SST-110 Steam Turbine Generator, Year 2018

467235
6745 kw Siemens SST-110 Steam Turbine Generator, Year 2018. Single Stage Back Pressure Turbine Design. Inlet Steam: 90,000 #/hr Steam at 850 PSI and 650 F. Exhaust Steam: 90,000 #/hr at 46 PSI and 375 F. Exhaust Steam Pressure is variable depending on process conditions. Includes: 8750 KVA AC Synchronous Generator Manufactured by TD Power Systems, Type TC150. Capacity: 7.0 MW / 13.8kV / 60 Hertz. Year 2018. System used less than one year due to complete plant closure. All controls and MCC panels are available. Desuperheater is available to control exhaust steam temperature. SPARE TURBINE ROTOR ASSEMBLY INCLUDED.

2200 HP Superior Firetube Boiler and Economizer; Natural Gas Fired

142067
2200 HP Superior Firetube Boiler and Economizer; Natural Gas Fired; Design Pressure: 150 PSIG. Superior Apache 2-Pass Dryback Scotch Marine Package Boiler Model 8-X-11000-S150-GPCF-G. Natural Gas firing rate IN 92,400 CFH at 1000 BTU/CF; 2200 Boiler HP (73,645 MBTU) Steam OUT ASME Nat'l Bd# 16198. A Cleaver Brooks Lo NOx < 30 ppm and 0.0364 lbs. per MMBTU burner was installed in 2015, Model LNXLG-924, serial 58734-1. Year of Manufacture: 2007. Includes controls and firing monitoring, gas train, forced draft blower, Kunkle safety valves 6x8" and 4x6" both set at 100 psig. Boiler dimensions are approx 151" w x 302" L x 153" tall. Approx overall floor space needed: 43.6 ft L x 19.3 ft W x 13.2 ft T (not including safety valves and economizer and stack). Cain economizer model RJR-166K26ALS. Stainless steel. Stack is Van-Packer Model DW 36" ID x 20'-9" long, ss304 insulated. See drawing and manual for verification. Weight empty approx 121,000 pounds. Idled 2018.

75,000 lbs/hr Babcock & Wilcox; 250 PSI

467130
75,000 lbs/hr. B&W Water Tube Boiler; 250 PSI Design Pressure. Year 2014. Includes Low NOx Natural Gas Burner with Flue Gas Return, Burner Mfg. by Faber; Operating Pressure 150 PSI; Total Heating Surface: 5925 Sq.ft.; Dry weight: 88,900 lbs.

77,000 Lb/Hr. Nebraska Boiler; MAWP: 300 PSI; Low NOx

467140
77,000 Lb/Hr. Nebraska Boiler Model: NS-E-63; MAWP: 300 PSI; Year 1996. Low NOx Coen Burner. BMS 2000 Burner Controls. Natural Gas Fired; Water Tube Boiler Design; Surface Area: 5346 Sq. Ft.; Economizer and Stack Included. DA Tank and Feedwater Pumps Available Separately.

5000 PPH Cleaver Brooks FLX 700/600 Water Tube Boiler

467028
Cleaver Brooks Model: FLX 700/600 Water Tube Boiler. 4,950 Lb/Hr. Steam Capacity, 150 PSI Pressure, Year 2019. Fuel: Natural Gas, Rated at 6,000,000 BTU/hr., Quantity Two (2).