Search
Picture for category Firetube Boilers

Firetube Boilers

800 HP Cleaver Brooks Boiler; 150 PSI; Year 2000

467115
800 HP Cleaver-Brooks Firetube Boiler; Model CBI-700-500-150; Year 2000; 150 PSI MAWP; Natural Gas Burner; Oil Pump; 15 HP Blower Motor, 480 V, 60 Hertz, 3-Phase. Pumps Available Separately.

Two (2) Superior Boilers 1200 HP and 800 HP Available Together

126394
Two (2) Superior Boilers 1200 HP and 800 HP Available Together. 1200 HP Superior Steam Boiler with Dual burners for Nat. Gas and #2 Fuel Oil; Model 6-5-6000 Heating Surface Area: 6000 Square Feet; Capacity: 41400 Lbs./Hr. Steam; Year 1998; Boiler was overhauled and reinstalled in good condition in 2007 and has seen only test hours since. 800 HP Superior Steam Boiler with Dual burners for Nat. Gas and #2 Fuel Oil; Model 6-5-4000 Heating Surface Area: 4000 Square Feet; Capacity: 27600 Lbs./Hr. Steam; Year 1993; Boiler was overhauled and reinstalled in good condition in 2007 and has seen only test hours since. Can include DA Tank and Condensate Return Tank and Feedwater Pumps.

500 HP Johnston 4-Pass Wet Back Boiler 150 PSI Fuel: NG / #2 Oil / #6 Oil

125954
500 HP Johnston 4-Pass Wet Back Boiler 150 PSI Fuel: NG / #2 Oil / #6 Oil Low NOx (30ppm) Burner. Year 2001.

2200 HP Superior Firetube Boiler and Economizer; Natural Gas Fired

142067
2200 HP Superior Firetube Boiler and Economizer; Natural Gas Fired; Design Pressure: 150 PSIG. Superior Apache 2-Pass Dryback Scotch Marine Package Boiler Model 8-X-11000-S150-GPCF-G. Natural Gas firing rate IN 92,400 CFH at 1000 BTU/CF; 2200 Boiler HP (73,645 MBTU) Steam OUT ASME Nat'l Bd# 16198. A Cleaver Brooks Lo NOx < 30 ppm and 0.0364 lbs. per MMBTU burner was installed in 2015, Model LNXLG-924, serial 58734-1. Year of Manufacture: 2007. Includes controls and firing monitoring, gas train, forced draft blower, Kunkle safety valves 6x8" and 4x6" both set at 100 psig. Boiler dimensions are approx 151" w x 302" L x 153" tall. Approx overall floor space needed: 43.6 ft L x 19.3 ft W x 13.2 ft T (not including safety valves and economizer and stack). Cain economizer model RJR-166K26ALS. Stainless steel. Stack is Van-Packer Model DW 36" ID x 20'-9" long, ss304 insulated. See drawing and manual for verification. Weight empty approx 121,000 pounds. Idled 2018.

500 HP Cleaver Brooks Boiler; 150 PSI; Year 2003

467110
500 HP Cleaver-Brooks Firetube Boiler; Model CBI-700-500-150; Year 2003; 150 PSI MAWP; Natural Gas Burner; Oil Pump; 15 HP Blower Motor, 480 V, 60 Hertz, 3-Phase. Economizer / Pumps Available Separately.