Surplus and Used Industrial Boilers - Package Boilers

 

6745 kw Siemens SST-110 Steam Turbine Generator, Year 2018

467235
6745 kw Siemens SST-110 Steam Turbine Generator, Year 2018. Single Stage Back Pressure Turbine Design. Inlet Steam: 90,000 #/hr Steam at 850 PSI and 650 F. Exhaust Steam: 90,000 #/hr at 46 PSI and 375 F. Exhaust Steam Pressure is variable depending on process conditions. Includes: 8750 KVA AC Synchronous Generator Manufactured by TD Power Systems, Type TC150. Capacity: 7.0 MW / 13.8kV / 60 Hertz. Year 2018. System used less than one year due to complete plant closure. All controls and MCC panels are available. Desuperheater is available to control exhaust steam temperature. SPARE TURBINE ROTOR ASSEMBLY INCLUDED.

90,000 #/Hr Victory Boiler, 950 PSI MAWP; 650°F Superheat; Year 2018; Model VS-5-78SP-SH

467230
90,000 #/Hr Victory Boiler, Model VS-5-78SP-SH; 837 PSIG Operating Pressure; 526°F Temperature; Year 2018 with COEN Natural Gas, Low NOx Burner. One (1) Shop Assembled Voyager Steam Generator; Heating Surface: Total 7344 Sq.Ft.; Superheater Surface: 980 Sq.Ft.; MAWP: 950 PSIG @ 650°F; Operating Pressure: 837 PSIG @ 526°F; Hydrostatic Test: 1425 PSIG. Feedwater Temperature: 227°F @ Control Valve; Fuel: Natural Gas; Installation: Outdoors; Empty Weight: 186,900 Lbs.; Flooded Weight: 232,000 Lbs.

800 HP Cleaver Brooks Boiler; 150 PSI; Year 2000

467115
800 HP Cleaver-Brooks Firetube Boiler; Model CBI-700-500-150; Year 2000; 150 PSI MAWP; Natural Gas Burner; Oil Pump; 15 HP Blower Motor, 480 V, 60 Hertz, 3-Phase. Pumps Available Separately.

77,000 Lb/Hr. Nebraska Boiler; MAWP: 300 PSI; Low NOx

467140
77,000 Lb/Hr. Nebraska Boiler Model: NS-E-63; MAWP: 300 PSI; Year 1996. Low NOx Coen Burner. BMS 2000 Burner Controls. Natural Gas Fired; Water Tube Boiler Design; Surface Area: 5346 Sq. Ft.; Economizer and Stack Included. DA Tank and Feedwater Pumps Available Separately.

30000 Lbs/Hr. Super Heater Model SH6G by FSE Energy. Year 2012

126769
30000 Lbs/Hr. Super Heater Model SH6G by FSE Energy. Year 2015; Unused/New Surplus. Natural Gas Fuel. Max Operating Pressure: 425 PSI; Max Operating Temperature: 750 F; Heat Capacity: 6000000 BTU. Input of 30k PPH 425 PSI Steam @ 437 F; Output of 30k PPH 410 PSI 750 F Superheated Steam. Never installed Power Distribution and Heater Management for Super Heater System used to convert saturated steam or wet steam into superheated steam or dry steam. Designed for use with Flu Gas Return. Power Flame Burner Model C8-G-30 Natural Gas.

70000 Lbs/Hr CS Deaerator System Manufactured by Cleaver Brooks

126352
70000 Lbs/Hr CS Deaerator System Manufactured by Cleaver Brooks Model Spray Master SM70-1400; Year Built 2002. Available Immediately As-is Where-is.

157,000 Lbs. / Hr. Tray Type Deaerator for Steam Boiler Feed

126338
157,000 Lbs. / Hr. Tray Type Deaerator for Steam Boiler Feedwater. Model TC-185, by Penn Manufacturing, Serial# 773. Top Section: 6 ft dia. x 5 ft tall.; Storage Section: 6'-6" dia. x 16' Long. Tank is 19'-10" OAL. 4000 Gallon Capacity. Shell Material: CS - SA-516-70; Trays SS430. Designed for Capacity Flow of 157,714 lb/hr. Outlet, 16,346 lb/hr. Steam Inlet. ASME NB# 457, MAWP 70 psi at 400F. Has 6 Spray Nozzles and 37 Trays. Weight: 13,700 lbs. Empty. Rests On Support Saddles. Used as Deaerator on Nebraska Boiler. Built 2007. Only in Service for Approximately 1 Year.

Goulds Model 3316; Size: 1.5 X 2 – 9; Type: Split Case Pump;

126774
Goulds Model 3316; Size: 1.5 X 2 – 9; Type: Split Case Pump; Material: Ductile Iron Casing Ductile Iron Impellers; Impeller Size: 8 3/4" Diameter 4-Vanes

Goulds 3316 1.5x2x9 Split Case Pump Ductile Iron Casing

126773
Goulds 3316 1.5x2x9 Split Case Pump Ductile Iron Casing 8 3/4" Ductile Iron Impeller

50,000 Lbs/Hr. Bio-Mass Gasification / Steam Boiler System

126762
50,000 Lbs/Hr. Bio-Mass Gasification / Steam Boiler System, Integrated by Siemens. Capacity: 50,000 Lbs/Hr. Saturated Steam at a Design Pressure of 150 PSIG. Fuel Consumption: 3.0 Tons/Hr. Blended Waste (Wood Flour and Shredded Polyester), or 5.0 Tons/Hr. Wood Flour. Total Energy: 59.30 – 76.57 MMBtu/hr. The PRME® Gasification Technology is fixed grate, up-draft, sub-stoichiometric and multi-zoned gasification system. A staged combustion process results in hot clean waste gases, which are then used to generate steam for plant consumption, and a waste stream of approximately 300 Lbs./Hr. of Ash. The Primenergy L.L.C. Gasification System includes equipment, instruments and controls designed for the Gasification of carpet waste / wood flour fuel for Syngas delivery to the Energy Recovery boiler. The Gasification System includes: Fuel Bucket Elevator; Reactor Infeed Rotary Airlock; Reactor Infeed Screw; PrimeEnergy KC- 17 Gasifier; Startup Gas Burner; Reactor Underfire Air Fan. According to the manufacturer the PrimeEnergy Gasification process is suitable for wood and wood waste, processed municipal solid waste (RDF), agricultural residues, paper mill sludge, wastewater treatment sludge. Offered separately for this system is a 400 HP Industrial Shredder, Granutech-Saturn Systems Model# M240H, 460V/3PH/60Hz. Chamber Size: 95” x 100”, Rotor Diameter: 20”. Formerly Used on Carpet. Manufacturer states that this model shredder is effective for Plastics, Fiber, Thin Film, Rigid Scrap, Carpet, Medical Waste, Product Destruction, Pallets, Document Destruction. Includes Hydraulic Pump Skid, Feed Conveyor, and was running until shutdown due to process change.

1500 HP Hurst Boiler Biomass Cogeneration System with 750 kw GTG

126663
1500 HP Hurst Boiler Biomass Cogeneration System with 1.0 MW Erie Steam Turbine. Hurst Boiler Capacity: 51750 Lbs/Hr.; Boiler Surface Area: 9750 Sq.Ft.; Design Pressure: 450 PSI; Model: HYD9750-450-1; Year 2009. Reciprocating Grate style Hurst Combustion Stoker Design. According to Hurst the reciprocating grate-type stoker system permits biomass fuels to be combusted in an efficient manner with the added advantage of automatic de-ashing; and Fuels include: Agricultural biomass wood bark agave fiber rice husk chicken manure sugar cane bagasse king grass MSW construction debris nuts shells husks paper card/board products hog fuel sawdust shavings and/or sludge. This is a complete system with feed conveyors boiler fuel metering DA Tank and Feedwater pumps Steam turbine controls wet ash disposal economizer ducting filter bag houses controls and wiring and (1) fabricated boiler feed storage silo.

2200 HP Superior Firetube Boiler and Economizer; Natural Gas Fired

142067
2200 HP Superior Firetube Boiler and Economizer; Natural Gas Fired; Design Pressure: 150 PSIG. Superior Apache 2-Pass Dryback Scotch Marine Package Boiler Model 8-X-11000-S150-GPCF-G. Natural Gas firing rate IN 92,400 CFH at 1000 BTU/CF; 2200 Boiler HP (73,645 MBTU) Steam OUT ASME Nat'l Bd# 16198. A Cleaver Brooks Lo NOx < 30 ppm and 0.0364 lbs. per MMBTU burner was installed in 2015, Model LNXLG-924, serial 58734-1. Year of Manufacture: 2007. Includes controls and firing monitoring, gas train, forced draft blower, Kunkle safety valves 6x8" and 4x6" both set at 100 psig. Boiler dimensions are approx 151" w x 302" L x 153" tall. Approx overall floor space needed: 43.6 ft L x 19.3 ft W x 13.2 ft T (not including safety valves and economizer and stack). Cain economizer model RJR-166K26ALS. Stainless steel. Stack is Van-Packer Model DW 36" ID x 20'-9" long, ss304 insulated. See drawing and manual for verification. Weight empty approx 121,000 pounds. Idled 2018.

500 HP Johnston 4-Pass Wet Back Boiler 150 PSI Fuel: NG / #2 Oil / #6 Oil

125954
500 HP Johnston 4-Pass Wet Back Boiler 150 PSI Fuel: NG / #2 Oil / #6 Oil Low NOx (30ppm) Burner. Year 2001.

Two (2) Superior Boilers 1200 HP and 800 HP Available Together

126394
Two (2) Superior Boilers 1200 HP and 800 HP Available Together. 1200 HP Superior Steam Boiler with Dual burners for Nat. Gas and #2 Fuel Oil; Model 6-5-6000 Heating Surface Area: 6000 Square Feet; Capacity: 41400 Lbs./Hr. Steam; Year 1998; Boiler was overhauled and reinstalled in good condition in 2007 and has seen only test hours since. 800 HP Superior Steam Boiler with Dual burners for Nat. Gas and #2 Fuel Oil; Model 6-5-4000 Heating Surface Area: 4000 Square Feet; Capacity: 27600 Lbs./Hr. Steam; Year 1993; Boiler was overhauled and reinstalled in good condition in 2007 and has seen only test hours since. Can include DA Tank and Condensate Return Tank and Feedwater Pumps.

251000 PPH Deltak HRSG designed for GE LM6000 Gas Turbine Generator

126049
251000 PPH Deltak HRSG designed for GE LM6000 Gas Turbine Generator. New in 2002. Quatity (2). Unused Surplus. 251000 Lbs./Hr. Steam at 950 PSI / 750 deg. F (Fired with Duct Burner). With Low Pressure Drum Capacity of 32000 Lbs./Hr. Steam at 72 PSI / 370 deg. F (Fired). (2) Complete Systems. As originally delivered packages to include: Duct Burner – Natural Gas Fired; HP Superheater; HP Desuperheater; HP Boiler; HP Economizer; LP Superheater; LP Boiler; LP Economizer; Duct Burner Elements; Feedwater Control Valve with Isolation & Bypass Valves; Feedwater Flow Element; Superheater Start Up Valves; Superheater Drain Valves; Desuperheater Stop Valves; Exhaust Expansion Joint; Inlet Gas Ducts; HP Steam Drum & Support Structure; LP Steam Drum & Support Structure; Boiler Trim; Motorized Valves; Walkways & Platforms; Outlet Expansion Joint; Outlet Stack and Transition; Outlet Stack EPA Connections; Outlet Stack Damper with Motor Actuator; HP & LP Boiler Steam Sparging lance with stop valve; Gas Train Fuel Piping Skid; Flame Management System; Feedwater Stop Valves.

75,000 lbs/hr Babcock & Wilcox; 250 PSI

467130
75,000 lbs/hr. B&W Water Tube Boiler; 250 PSI Design Pressure. Year 2014. Includes Low NOx Natural Gas Burner with Flue Gas Return, Burner Mfg. by Faber; Operating Pressure 150 PSI; Total Heating Surface: 5925 Sq.ft.; Dry weight: 88,900 lbs.

Rentech Waste Heat Recovery Boiler

467063
WHRU – Rentech Hot Water Boiler rated for 690,000 lbs. water an hour (1,377 GPM). A combustion exhaust stream is used to heat approximately 690,000 pounds of water per hour from 170 °F to 225 °F at an ambient condition of 55 °F. Designed for use with a Solar Turbines, Taurus 70 Gas Turbine Generator.

214000 Lbs/Hr. Cleaver Brooks / Nebraska; Natural Gas Water

126817
214000 Lbs/Hr. Cleaver Brooks / Nebraska; Natural Gas Water Tube Boiler. Rated for 450 PSI Design Pressure; 650 F Design Temp; 360 PSI Operating Pressure; 590 F Operating Temp with 227F Feedwater Temperature.

Fuel: Natural Gas at 285mm BTU/hr. 8 to 1 Turndown. Low NOx burner. Year 2011 / Installed 2013.

Only has 80 Hours of use in service testing. Includes Deaerator; All controls; FD Fan; Economizer and Stack.

Weight: 142423 Lbs Dry

Dimensions: 42’-6.5” L x 12’-10.5” W x 15’-11” H

230000 Lbs/Hr. (104 MT/hour) 1200 PSI (82.7 Bar) Operating Presssure

126807
230000 Lbs/Hr. (104 MT/hour) 1200 PSI (82.7 Bar) Operating Pressure and 925℉ (496℃) Temperature. Alstom Industrial Package Boiler Model 43A16-48” Year 2002. Includes a Dual Fuel Natcom Hypermix (335 MMBtu/Hr) Low NOx Burner for Natural Gas or Diesel #2 fuel. Fireye Burner Safety and UV Flame Scanner. The high pressure package boiler has an A-Frame design with a 48” Diameter Steam Drum rated for 1400 PSIG (96.5 Bar) MAWP and two (2) 18” diameter mud drums. Manufacturer: Alstom Power Energy Recovery. Includes Boiler Valves and Instrumentation and all available drawings and manuals. Dimensions: 54’ L x 21’ H x 13’ W. Dry Weight: 347000 Lbs.

27587 Lbs/Hr. (800 HP) 290 PSIG MAWP RENTECH WaterTube Bio-mass Boiler

126334
27587 Lbs/Hr. (800 HP) 290 PSIG MAWP RENTECH WaterTube Bio-mass Boiler. UNUSED Surplus Never Installed. Constructed in strict accordance with ASME code Section I 2010 edition 2011 addenda. Stamped and registered with the national board. MAWP: 290 PSIG/FV; Hydrotest Pressure: 435 PSIG; Design Temperature 500°F (700°F TUBES); Weight: 65000 LBS (Dry) 92000 LBS (Full) 87000 LBS (Operating). Dimensions: 23'-6" L x 8'-3/4" W x 13'-3" H. Built Year 2012. Includes Hoppers Boiler trim and Catwalks. See Drawings for more details. Available Due to Cancelled Project.
Close
Filters Clear All